SECTION 9: WIRING AND ELECTRICAL INFORMATION
29 of 85
9.4 Wiring Diagram Oil Models 15-30 (floor standing)
NOTES:
1. C O NTROL WIRE TO BE A MINIMUM OF 1 mmØ ,FLEXING TYPE,
HAVING A TEMPERATURE RATING OF A LEAST 105°C AND 600V OR EQUIVALENT.
COLORS 230 VAC: PHASE-BROWN, NEUTRAL-BLUE, GROUND-GREEN/YELLOW.
2. ALL WIRING SHALL BE IDENTIFIED AT BOTH ENDS, WITH CABLE BEING IDENTIFIED WITH
THE SAME TERMINAL NUMBER TO WHICH IT IS CONNECTED TO IN THE CONTROL PANEL.
MAIN TERMINALS LOCATED IN CONTROL PANEL.
WIRE(S) LOCATED IN CONTROL PANEL.
WIRE(S) LOCATED IN FIELD.
6
N
OIL BURNER 7
WAY PLUG
L1
N
T1
T2
S3
B4
7 POLE SOCKET
GROUND
NEUTRAL
BURNER RUN
LOCK-OUT
LAMP
FLAME LAMP
LIVE
SIGNAL
L1
N
T1
T2
S3
B4
7 POLE PLUG
BROWN
BLUE
L1
L1
N
T1
T2
S3
B4
L1
N
T1
T2
S3
B4
PACKAGED BURNER
R
R N.C
2
BROWN
1
5
R N.O
31
BROWN
BLUE
P.S N.O
LOCKOUT
BROWN
BLUE
4
PRESSURE SWITCH
4.8 MBAR (1.96"W.C)
BREAKER 10 AMP
TIME / TEMPERATURE CONTROLS
3
BLUE
BROWN
2
BROWN
BROWN
GREEN/YELLOW
BROWN
FAN
LIMIT
BROWN
BROWN
N
L1
MAIN FAN MOTOR
BLUE
BROWN
BROWN
FAN CONTROL (OPTIONAL)
BROWN
L2
L3
FAN/LIMIT STAT
GREEN/YELLOW
230 V
1 ph
50 Hz
1
RELAY
NOTE:
Any of the original wire supplied with the heater must
be replaced with wiring material having a temperature
rating of at least 105°C (221°F) and 600 V.